    1. Currently, there is a significant lack of transparency of environmental cost, which should be urgently resolved given the vast scale of resource usage. Therefore, NGIatlantic.eu invites EU – US applicants that can provide and experiment with transparency mechanisms on the environmental cost of the Internet. Identification and tagging of most resource consuming elements are also very important and urgent. On both sides of the Atlantic, there has already been some early research and innovation projects and initiatives focussing on alternatives to improving energy efficiency to ensure the greening and sustainability of the Internet and of the economy relying on it. This topic welcomes the results from these EU activities to team up with US teams (or vice versa, with US teams twinning with EU teams) to carry out experiments in this vitally important NGI topic.

      Interesting. I couldn't see many in the link though.

    1. That will allow the utility to match in real-time specific units of renewable energy generation with Microsoft’s usage – and dispatch energy from storage if there’s a shortfall – to ensure Microsoft is continually supplied with renewable energy, Janous said.

      They ARE pairing it with batteries

    1. Typically, a data center is seen as an inflexible load, or a “single block” of power, she said. In other words, if the facility’s total load is 10MW, the conventional approach is to ensure there’s 10MW of backup power. Google has learned to not treat total load as an inflexible block and match backup capacity more tightly with the capacity required by applications that run in the facility and the duration for which it’s required.

      This is a good summary of carbon-aware compute.

    2. Also this year, Microsoft announced a successful test for powering a data center rack with a hydrogen-fueled automotive fuel cell, looking at the technology as one of the potential replacements for diesel generators.

      Bosch sell these now, or are making them.

      https://www.bosch.com/research/know-how/success-stories/high-temperature-fuel-cell-systems/

      There's also a collosal amount of EU money in creating a hydrogen economy, so it feels like there conditions are good for switching.

    3. Google estimates that the total generation capacity of all diesel-fueled data center backup generators deployed worldwide is more than 20 gigawatts, which could spell vast opportunities for renewable energy storage.

      20 gigawatts needed to replace all fossil generators worldwide.

      Not sure how long diesel generators last - 12 hrs? 24hrs?

    4. Maud Texier, Google’s carbon free energy lead

      Maud is the lead person on making Making DC's an active part of a future, responsive, sustainable grid

    1. But proponents of immersion cooling technologies emphasize their efficiency advantages. These solutions don’t require any fans. Server fans are usually removed altogether. “You can probably get at least a 15-percent energy reduction in a lot of environments by going to liquid cooling,” Brown said.

      I didn't know that liquid cooling was more energy efficient than air cooling. I also didn't really think about it much either, but it make sense. Liquid is a better conductor of heat than air in cooking, so…

    2. As Uptime’s Lawrence pointed out, generators are “a problem.” They are expensive to deploy and maintain, they pollute the atmosphere, and make a lot of noise. So far, however, they’ve been an indispensable part of any data center that’s meant to keep running around the clock.

      Wow, I didn't know the direction of travel away from diesel was so pronounced in DCs. Makes sense tho.

    1. Perhaps the most critical feature of a decentralized UPS architecture is it allows data centers to meet increased demand by deploying equipment-specific resources that can scale according to needs. New cabinets can expand capacity as necessary, while additional rectifiers and battery modules can increase power for servers added to open racks. By relying on DC power components that connect directly to the AC utility feed, a decentralized power architecture allows facilities to operationalize stranded white space and maximize infrastructure without placing any additional strain on their existing UPS system.

      Oh wow, so they decentralise INSIDE the datacentre. Would this mean it's would be easier to move loads (as in power usage) around in the DC, and power down entire sections more easily?

  2. Nov 2020
    1. We’re now 100% powered by renewable and sustainable energy which is great in further minimizing our impact on the planet. Plausible Analytics script weights less than 1 KB which is more than 45 times smaller than the recommended Google Analytics Global Site Tag implementation.

      After speaking to the folks at Plausible they pointed me to this page on the digital ocean community forums:

      https://www.digitalocean.com/community/questions/what-kind-of-electricity-do-you-run-on

      And this one here:

      https://www.interxion.com/why-interxion/sustainability

      The TLDR version is that the servers they are using are run by Digital Ocean, who lease from Interxion, who source the power for the datacentre from renewables.

      Interxion themselves are owned by Digital Realty, who do release figures, but not at a granularity to confirm.

      Once there is info from Interxion, it's possible to confirm this.